Series 2000 Cold-Light Fluorimeter CLF1 & CLF2

Summary

The Series 2000 Cold Light Fluorescence Detector CLF1 & CLF2 uses flow through sampling and results are outputted to the Microstream data processor via an analogue output socket. The fluorimeters are fixed wavelength instruments using a high brightness excitation source and emition cutoff filters. The detection limit for quinine sultphate is 0.1ppb. 32 Fluorescence methods for automatic analysis have been developed and one particularly for low level Aluminium in clinical determination. New manual methods can be adapted.

Features

Ideally suited for:

  • Pharmaceutical Analysis
  • Environmental Analysis
  • Sea water & Beverages
  • Medical Science
  • and more...!

Product Details

The Series 2000 Cold Light Fluorescence Detector is an important addition to the range of analytical instruments for continuous flow analysis, flow injection and process control analysis. The introduction of this detector compliments and extends the capabilities of Burkard continuous flow technology where levels of sensitivity can now be significantly improved. Its application in areas of pharmaceutical quality assurance, routine environmental analysis, beverage testing procedures, medical science and others has demonstrated improved performance by up to a factor of 10.

Operation

The CLF1 & CLF2 use flow through sampling and results are outputted to the Microstream data processor via an analogue output socket. The fluorimeter has been constructed as a fixed wavelength instrument using twin high brightness light sources for excitation. Solid state ultraviolet (UV) excitation offers increased energy, lower cost and longer life compared to traditional bulky (UV) light sources. The absence of heat avoids drift during operation and as the bandwidth of these devices (15-20 nm) is similar to interference filters an excitation filter is not required. A lower cost cut-off filter is supplied for the emission light output, which is detected by silicon photo-diode. Wavelength change involves the replacement of the fixed pre-positioned light source and cut-off filter of the appropriate wavelength.

Applications

Standard flow cells of various volumes are available for fluorescence applications or when the instrument is used as a nephelometer for measuring turbidity in water samples. With some electronic change the instrument can be configured for luminometry measuring low light levels from bioluminescence. The setup for nephelometry is identical to that for fluorimetry. A heated flowcell assembly is provided for enzymatic determinations. The detection limit for quinine sultphate is 1 ppb.

32 Fluorescence methods for automatic analysis have been developed and one particularly for low level Aluminium in clinical determination. New manual methods can be adapted. The following list is just a few of the compounds that have been analysed by using fluorescence, either in flow analysis systems or by chromatography. For compounds not on this list please contact us.

DNA
Aluminium
Albumin
Lactate
Boron
Bile acids
Mercury
Hydrogen peroxide
Cerium(IV)
Urea
Galactosidase

Histidine
Phenylalanine
Gallium
IgG
Copper
Pyridoxal
Manganese
Ochratoxin A
Vitamin B1
Quinine
Rhodamine G

Histamine
Glycine Glucose
Terbium
Cyanide
Pyridoxal-5-phosphate
Iron Cerium(III)
Cyclophosphamide
Phosphate

Instrumentation

In addition to the Series 2000 Fluorimeter, Burkard can supply a range of autosamplers, pumps, injection valves, chemistry manifolds and data acquisition systems to provide a completely automatic system for analysis by fluorescence.

All systems are supplied with fully developed methods. Installation on site is provided together with full training in the technique and in the use of the Data System. Burkard Scientific would also be pleased to carry out method development and to assist in the validation of the method and instrumentation.

Specifications

Fluorimeter Type

CLF1 & CLF2 'Cold light'

Cell Size

10 x 10mm, 100ul & 450ul UV

Excitation Wavelength

Typically: 356 - 420nm and higher
Bandwidth: 15 - 20nm

Light Intensity

Up to 1mW variable

Gain Control Adjust

X1 to X11 amplification

Emission Filters

Full range of cut off filters available

Analogue Output

Standard: 0-200mV
Alternative ranges: 0-1mV & 0-5V
Connection via 3 pin din plug and socket.
Compatible with recorder and MicroStream data-processor

Detection Limit

Down to 1ppb Quinine Sulphate standard

Case size

400 x 190 x 160mm

Supply voltage

110V 50-60Hz T 5A
240V 50-60Hz T 2.5A

Weight

3.8 Kg

The company reserves the right to change specification without notice.

Printable Product Datasheet (PDF)



Download Acrobat Reader